How Long Is The Life Of The Infrared Quartz Heating Tube?

Nov 15, 2021

Structure description:

The infrared quartz heating tube is a transparent quartz glass tube processed by a special process, equipped with a high-temperature heating wire, and the quartz glass tube is filled with inert gas. After being energized, it can protect the infrared quartz heating tube under high temperature conditions. , Extend the service life of the heating tube. Generally, halogen or tungsten gas is used as the protective gas in the infrared quartz heating tube.


Life factor:

1. Pipe wall load. The life of the load headlamp is low, the same working current, the lamp diameter is small, the life is low;

2. Working voltage. The lamp tube voltage is too high and the service life is reduced;

3. Power density. High power density and low lamp life;

4. The influence of the filament. Infrared quartz heating tube has thin filament and low life

5. The quality of the quartz glass tube wall has a great influence on the life of the lamp. Good quartz glass has high purity, no bubbles inside, and smooth surface. Because the tube wall temperature is generally above 900°C, if the purity is not enough, there will be impurities on the glass surface, which will produce many tiny pits, which will affect the infrared radiation out of the tube wall;

6. How to use. Incorrect use will greatly reduce the life of the lamp.


Installation and maintenance:

one. Wipe the lamp tube clean with ethanol before installation, and then wear clean gloves to hold the lamp tube;

two. Install or replace the infrared quartz heating tube, and turn off the power when cleaning the lamp shade, otherwise electric shock may occur;

three. Install the heating tube in place, hold the lamp cap with your hand and swing it on the holder a few times to observe whether the heating tube is in a free state, so that there will be no bursting phenomenon during use;

Four. In the parameter design, the transformer parameters and the lamp parameters must be matched, and the voltage and current cannot exceed the design indicators. Especially the starting voltage should not be too high;

five. Keep the pipe wall clean, especially to remove oil stains and dust. Because these substances will penetrate into the lamp tube on the surface of the high-temperature tube wall, hindering the efficiency of infrared radiation.


Reminder: When installing the heating tube, clamp the porcelain head into the clamp at the same time. It must not be clamped to one side first, otherwise the lamp tube will be easily broken at the pressure seal.