How Should Terminal Positions and Cold Sections Be Specified in Custom Spiral Tubular Heaters?

Oct 20, 2026

When developing a custom spiral tubular heater, getting the circular heating shape right is only part of the job. The terminal position, unheated section, and lead-wire arrangement must also fit the equipment's available installation space.

For OEM manufacturers of ovens, food-processing machinery, and compact heating equipment, these details can affect assembly, electrical connection, and maintenance access. A heater may match the required overall shape but still be difficult to install if its terminal ends point in the wrong direction or its lead wires interfere with nearby components.

This guide explains what to define when specifying the terminal configuration of a custom spiral tubular heater.

info-1500-1500

1. Why Does Terminal Position Matter?

The terminal position determines how the heating element connects to the equipment's electrical circuit. In a compact assembly, the available space around the heater may be limited by mounting brackets, sheet-metal panels, insulation, sensors, or other components.

Consider a flat spiral tubular heater installed inside an oven. The circular heating section may fit the available space, but the terminal ends could extend toward a panel or occupy the same space as a mounting feature. The heating element would then require a design review before installation.

To avoid this problem, specify more than the general location of the terminals. The drawing should indicate:

  • The point or side from which the terminals exit.
  • The direction in which the terminals or lead wires extend.
  • Whether the connection is straight or requires an angled arrangement.
  • The available clearance around the connection area.
  • Any nearby components that the terminal assembly must avoid.

Words such as "left side," "right side," or "facing outward" can be ambiguous without a defined viewing direction. A dimensioned drawing with a clear reference view is more reliable.

info-1500-1500

2. What Is the Difference Between a Cold Section and a Lead Wire?

These two details are related to the terminal arrangement, but they describe different parts of the assembly.

A cold section, also called a non-heating section in some specifications, refers to a designated section of the tubular heater that is not intended to act as the active heating zone. Its required length depends on the heater construction and the application's thermal conditions.

A lead wire is the external electrical wire used to connect the heater to the power supply or control system.

The length of the cold section is therefore not the same as the lead-wire length. Specifying a 100 mm lead wire, for example, does not automatically define how much of the metal tube must remain outside the active heating zone.

For a custom spiral tubular heater, clarify both requirements separately wherever applicable:

  • Required non-heating section length at the terminal end.
  • Lead-wire type and length.
  • Where lead-wire length should be measured from.
  • Required termination, connector, or terminal-pin arrangement.

The exact construction and measurement references should be confirmed on the approved drawing rather than assumed from a general description.

info-1500-1500

3. How Should Terminal Details Be Shown on the Drawing?

A useful drawing should make the terminal arrangement understandable without relying on an informal explanation.

Define the viewing direction. Include a clear front or top view of the spiral and identify the direction from which the terminal arrangement is shown. Add a side or profile view if the terminals extend out of the plane of the coil.

Show the exit direction. Draw the terminal pins or lead wires as part of the assembly, not as an unspecified detail outside the heater outline. If an angled exit is required, indicate the angle and the reference plane.

Dimension the connection area. State the required terminal spacing, exposed length, lead length, and other critical dimensions that affect installation. Identify the measurement starting point and endpoint wherever a length could be interpreted in different ways.

Specify the connection type. Clarify whether the equipment uses terminal pins, attached lead wires, or another agreed connection arrangement. Include connector details or mating-interface dimensions if these are relevant to the project.

Not every project needs an elaborate engineering drawing at the first inquiry stage. A clear sketch with the heater outline, terminal direction, basic dimensions, and connection requirements can help begin the feasibility review.

4. What Should OEMs Check About the Installation Space?

The connection area should be evaluated alongside the heater's intended operating environment.

First, check whether the terminals and lead wires have enough room to connect without being forced against nearby structures. Sharp edges, moving components, and mounting hardware may restrict the available routing path.

Second, consider the thermal conditions around the terminal end. Electrical connection materials and lead-wire insulation must be suitable for the temperatures they will actually encounter. A designated cold section can help separate the connection area from the active heating zone, but it does not guarantee that the terminal area will remain cool under every installation condition.

Third, confirm whether the connection needs to be accessible for assembly, inspection, or maintenance. The appropriate layout may differ between a heater installed during machine manufacture and one that must be disconnected during later servicing.

There is no single cold-section length or terminal clearance that suits every spiral tubular heater. The requirements should be evaluated against the heater construction, installation layout, and operating conditions.

5. What Common Specification Mistakes Should Be Avoided?

Several small omissions can result in avoidable clarification during custom heater development.

Specifying only the lead-wire length. This leaves the required cold section and terminal arrangement undefined.

Showing the terminal location without a reference view. The manufacturer may interpret the direction differently from the equipment designer.

Ignoring the connection space. A terminal arrangement can meet the drawing dimensions but still conflict with nearby equipment components if the surrounding clearances are not shown.

Changing the terminal arrangement after sample approval. Moving an exit point or changing an angled connection can affect the formed configuration and the installation interface. Such changes should be reviewed and documented before batch production.

Before approving a custom spiral tubular heater, confirm the connection details on the same drawing revision that defines the heater configuration.

Frequently Asked Questions

Can the terminals of a spiral tubular heater be customized?

The terminal arrangement can be reviewed for a custom project. Feasibility depends on the heater construction, required geometry, connection type, and installation constraints.

Is lead-wire length the same as cold-section length?

No. Lead-wire length refers to the external electrical wire, while the cold section refers to a designated non-heating section of the tubular heater. They should be specified separately where applicable.

What should I send when requesting a custom terminal arrangement?

Provide the heater drawing or sketch, voltage, wattage, terminal direction, required lead-wire and cold-section lengths, connection details, and estimated quantity. Include the available installation space or relevant photographs if possible.

Can terminal placement affect installation even when the spiral diameter is correct?

Yes. The overall coil can fit within the available space while the terminal ends or lead wires interfere with surrounding components. Both the heating profile and the connection area should be reviewed before production approval.

modular-1
Custom Spiral Tubular Heaters for OEM Equipment in China

JAYE Heater Technology manufactures customized heating elements for equipment manufacturers.

When reviewing a custom spiral tubular heater project, the manufacturing feasibility review can include the terminal arrangement, designated cold section, lead-wire requirements, and critical installation dimensions.