1) After checking that the mold size is consistent with the design drawing, spray the nozzle sealing surface and the nozzle mounting datum support surface with red lead, and then lightly install it into the mold. After confirming that the hot runner nozzle is installed in place, take out the nozzle and check whether the nozzle sealing surface and the supporting surface are in place.
2) Insert the center positioning pin, anti-rotation positioning pin, and center spacer block, and then put the sealing ring into the "O" ring groove on the upper end surface of the hot runner.
3) Install the manifold, (lock the manifold with screws), the upper pressure block, and the hot runner manifold thermocouple.
4) In order to facilitate wiring, connect the lead wires of each power supply and hot runner thermocouple heating coil and number them with number tubes.
5) After the assembly is completed, use a depth gauge to measure whether the height of the pressure pad on the manifold is the same as the height of the manifold pad (the general standard is that the upper pad is 10-20 divisions higher than the mold pad), confirm the height, and then cover the mold. Cover and tighten the cover screws.
6) Wiring: Put the power cord into the outlet slot and fix it with a crimping plate. After confirmation, cut off the excess cord and insert it into the φ2-3 terminal. Confirm the connector: HUIGER's standard is that the power cord is connected to the male core connector, and the hot runner thermocouple is connected to the female core connector.
7) There are generally two situations for field wiring: one is to connect to the connector according to the HUIGER wiring method. The other is connected to the connector according to the wiring provided by the customer.
8) After wiring is completed, put the connector into the junction box and fix it on the mold.
9) After the assembly is completed, use a multimeter to check whether the resistance value and insulation value of (hot runner heater and thermocouple) are normal.
Previous: Correct Usage of Heating Tube
Next: What is the principle of the electric heating plate of the rice cooker?